Vibration Control of Building Using Base Isolation Under Near Fault Earthquakes
International Journal of Civil Engineering |
© 2020 by SSRG - IJCE Journal |
Volume 7 Issue 7 |
Year of Publication : 2020 |
Authors : Richa F. Chauhan, Snehal V. Mevada, Vishal B. Patel |
How to Cite?
Richa F. Chauhan, Snehal V. Mevada, Vishal B. Patel, "Vibration Control of Building Using Base Isolation Under Near Fault Earthquakes," SSRG International Journal of Civil Engineering, vol. 7, no. 7, pp. 65-72, 2020. Crossref, https://doi.org/10.14445/23488352/IJCE-V7I7P109
Abstract:
The seismic response of a single-story symmetric building with laminated rubber bearing(LRB) is investigated. The comparative performance of laminated rubber bearing isolation investigated for single storey symmetric building under selected past earthquake ground motions. The seismic response is obtained by numerically solving the governing equations of motion using the state-space solution. The behavior of LRB and fixed base structure is studied through various response parameters such as floor acceleration, floor relative displacement, mass ratio, isolator displacement, and isolator force. It is observed that the LRB base isolated system is quite effective in reducing various seismic responses.
Keywords:
Symmetric Building, Seismic Response, Optimum, Base isolation, Near fault earthquake
References:
[1] R.S.Jangid and Jeevan Kulkurni, Rigid body response of base-isolated structure, Journal of Structural Control, 9 (2002) 171-188.
[2] V.A.Matsagr and R.S.Jangid Base isolated building with asymmetries due to the isolator parameters, Journal of Advanced in Structural Engineering, 8(6)(2005) 603-622.
[3] V.A.Matsagr and R.S.Jangid Seismic response of base-isolated bridge with different isolator, International Journal of Applied Science and Engineering, 4(1)(2006) 53-69.
[4] R.S.Jangid and J.M.Kelly Base isolation for near-fault earthquake, Journal of Earthquake Engineering And Structural Dynamic, 30(2001) 691-707.
[5] Ajay Sharma and R.S.Jangid Behaviour of base-isolated structure with high initial isolator stiffness, International Journal of Applied science, Engineering and Technology, 5(3)(2009) 199-204.
[6] R.S.Jangid And T.K.Dutta Nonlinear response of torsionally coupled base-isolated structure, Journal of Structural Engineering, 120 (1)(1994) ,1-22.
[7] V.A.Matsagar and R.S.Jangid Impact Response of Torsionally Coupled Base-isolated Structures, Journal of vibration and control, 1(27)(2008) 1-27.
[8] R.S.Jangid Optimum lead rubber isolation bearing for near-fault motions, ELSEVIER/Engineering Structure, 29(2007) 2503-2513.
[9] D.P.Soni, B.B.Mistry, and V.R.Panchal Behavior of asymmetric building with double variable frequency pendulum isolator, Structural Engineering and Mechanics, 34 (1)(2010) 61-84.
[10] R.S.Jangid and T.K.Dutta Performance of base isolation systems for asymmetric building subject to random excitation”, Engineering Structure, 17(6)(1995) 443-454.
[11] Mbamaluikem Peter O, Bitrus, Irmiya, Okeke, Henry S. Asymmetrical Fault Recognition System on Electric Power Lines Using Artificial Neural Network International Journal of Engineering Trends and Technology 67(11) (2019).