Analysis of Partial Discharge Model Under Various Stress Conditions

International Journal of Electrical and Electronics Engineering
© 2020 by SSRG - IJEEE Journal
Volume 7 Issue 2
Year of Publication : 2020
Authors : Naila Bano, Agha Zafarullah, Mohsin Ali
pdf
How to Cite?

Naila Bano, Agha Zafarullah, Mohsin Ali, "Analysis of Partial Discharge Model Under Various Stress Conditions," SSRG International Journal of Electrical and Electronics Engineering, vol. 7,  no. 2, pp. 14-17, 2020. Crossref, https://doi.org/10.14445/23488379/IJEEE-V7I2P103

Abstract:

The existence of cavity in solid insulation, repetition of PD activities is one of the key sources of insulation degradation, which could lead to breakdown. Therefore, continuously monitoring of insulation is very important through PD data. Therefore, in this work PD model within a cavity in solid insulation is done and parameters related to electron generation is analyzed using an optimization technique.

Keywords:

Condition Monitoring, Power Cable, Insulation Degradation

References:

[1] Asima Sabat and S. Karmakar, “Simulation of Partial Discharge in High Voltage Power Equipment”,International Journal on Electrical Engineering and Informatics ‐ Vol.3, Number 2, 2011
[2] Y. Z. Arief, W. A. Izzati, Z. Adzis, “Modeling of Partial Discharge Mechanisms in Solid Dielectric Material”,International Journal of Engineering and Innovative Technology (IJEIT)Vol1, Issue 4, April 2012.
[3] Pragati Sharma1, ArtiBhanddakkar, “Simulation Model of Partial Discharge in Power Equipment”, International Journal of Electrical and Electronics Research Vol. 3, Issue 1, pp: (149-155), Month: January - March 2015.
[4] M.U. Zuberi, A. Masood, M.F. Khan, Ekram Hussain and A. Anwar, “Estimation of Partial Discharge Inspection Voltages due to Voids in Power Cables”, International Conference on Energy &Eniviroment, University of Cambridge, UK, February 23-25, 2008.
[5] Asima Sabat,“Characteristics Study of Partial Discharge in Solid Insulation Due to Presence of Cylindrical Void”,Internationa Journal of Scientific Reasarch and Educaion, Vol. 3, Issue 4, April-2015
[6] Adel ElFaraskoury, Mostafa Mokhtar, Mohamed Mehanna, Ossma Gouda, “Conventional and Un-Conventional Partial Discharge Detection Methods in High Voltage XLPE Cable Accessories”, Advances in Electrical Engineering Systems (AEES),Vol. 1, No. 4, 2012
[7] Nidhi Singh, SunhraDebdas,Rajeev Chauhan, “Simulation & Experimental Study of Partial Discharge in Insulationg Materials for High Voltage Power Equipments”, International Journal of Scientific & Engineering Reaserch, Vol. 4, issue 12, Dec. 2013
[8] S.Gopinath and K.Sathiyasekar “Simulation of Partial Discharges in Solid Dielectric Material: A Study on PD Magnitudes to the Parallel and Perpendicular Axis of a Cylindrical Cavity”, International Journal of Engineering and Technology (IJET)Vol. 6. No. 4 Aug-Sep 2014.
[9] Jasmin James,S.V.Kulkarni, B.R.Parekh, “Partial discharge in High Voltage Equipments-HV Cable”, International Electrical Electronics Engineering, July 19-23,2009
[10] M. Kida, T. Kawashima, Y. Murakami, M. Nagao, "AC Partial Dischatge Characteristic at Minute Air Gap under Non-uniform Electric Field", International Electrical Electronics Engineering, 2015.
[11] Oleg Emelyanov, Pavel Kliuiko, Mikhail Shemet, "Single Partial Discharge in Non-uniform Electric Field for Different Polymer Dielectrics", International Electrical Electronics Engineering, 2016.