Upasana Sharma and Jaswinder Kaur, "Evaluation of Various Reliability Measures of Three Unit Standby System Consisting of One Standby Unit and One Generator," SSRG International Journal of Industrial Engineering, vol. 3,  no. 2, pp. 28-32, 2016. Crossref, https://doi.org/10.14445/23499362/IJIE-V3I4P107

Abstract:

The paper presents reliability measures of compressor standby system which consist of three compressor units and one generator. Initially two compressor units are in functioning state while third compressor unit and generator are in standby state. For system operation working of at least two compressor units is must. System can interrupt due to failure of compressor unit and halt in electricity .These constraints can be overcome by using standby compressor unit and generator. For practical utility many years real failure and repair data has been collected from Verka milk plant to evaluate various measures of reliability effectiveness such as MTSF, availability ,busy period and profit. All these measures have been computed numerically as well as graphically by using semi Markov process and regenerative point technique.

Keywords:

Regenerative technique ,semi-Markov process, refrigeration system.

References:

[1] D.P.Gaver, “Time to failure and availability of parallel systems with repair”, IEEE Trans. Reliab., 12, 30-38,1963.
[2] R.Narang and U. Sharma , “Analysis of two unit standby oil delivering system with two types of repair facility and priority is given to partially failed unit with provision of switching over to another system”, International journal of engineering sciences & research  technology , Vol. 3, No. 06, 117-123 ,June2014
[3] M.C.Rander, A.Kumar and R.K.Tuteja, R, “A two-unit cold standby system with major and minor failures and preparation time in the case of major failure”. Microelectron. Reliab., 32,1199-1204,  1991
[4] U.Sharma and J. kaur , “Profit evaluation of three units compressor standby system”,International journal of advanced research trends in engineering and technology,     vol 3 , no 5  ,26-30, May 2016
[5] R.K. Tuteja and G.Taneja, “Profit analysis of a one-server one-unit system with partial failure subject to random inspection”, Microelectron.  Reliab., 33,319-322, 1993.
[6] M.Yamashem , “A repairable multiple state device with general repair time”, IEEE, Trans. Reliab., R-29, 276, 1980
[7] Z.Zhang ,W. Gao  and Y.Zhou Y , “Reliability modelling and maintenance optimization of the diesel system in locomotives”, Maintenance and reliability , Vol 14,No 4, 302-311 , 2012