Abstract:
Frequent breakage of maxillary complete denture prosthesis is a source of dissatisfaction to the patient and thus identifying the underlying cause of such mechanical failures is mandatory to solve the problem. We present a case of an elderly female patient who reported with a history of two maxillary dentures both breaking in the midline. Maxillo mandibular ridge relations were the primary cause of fracture. The maxillary and mandibular residual alveolar ridges were aligned parallel to each other posteriorly due to which the direction of the forces generated by the mandibular closure were focussing on the midline of the maxillary complete denture. A metal denture base was fabricated for the maxillary complete denture to which denture base resin was added. The patients lower third facial height was restored to normal, which removed her pseudo prognathism that was related to decreased lower third facial height.
Keywords:
midline denture fracture, denture repair, base metal alloy, vertical dimensions of face, free way space
References:
[1] Peyton FA. “History of resins in dentistry”. Dent Clin North Am 1975;19:211-22.
[2] Grunewald AH. Gold base lower dentures. J Prosthet Dent 1964;14:432-41.
[3] Mattoo KA, Krati J. “Multiple maxillary tuberosity exostoses. J Med Sci Clin Res”. Jan 2015; 3 : 4389-91
[4] Rahman S, Deep A, Mattoo KA. “Bony Exostoses on Hard Palate - Prosthetic Inferences”. Archives of Dentistry and Oral Health. 2019; 2: 01-03
[5] Belfiglio EJ. “Using metal base in making complete dentures.” J Prosthet Dent 1987;58:314-7.
[6] Mattoo KA, Shikha. “A novel impression technique for recording bilateral severe undercuts with rigid impression materials in completely edentulous patients”. Int Dent J Students Research, 2016; 4: 163-66
[7] Kapoor A, Singh M, Mattoo KA. “Abridged duplication of palatal rugae for complete denture prosthesis”. SSRG International Journal of Medical Science 2019; 6 : 1-2
[8] Mattoo KA, Khare S, Nagaraj K. “Characterizing extreme dehiscence of a maxillary molar”. American Journal of Medical Case Reports 2015; 3: 13-15
[9] Mattoo KA and Sarvar S. “Characterizing Single Complete Denture Opposing Natural Teeth and Partial Denture”. J Dental Sci 2017;2 : 000148.
[10] Allen LR. “Improved phonetics in denture construction”. J Prosthet Dent 1958;8:753-63.
[11] Phillips RW. “Skinner’s science of dental materials. 9th ed. Philadelphia: WB Saunders”, 1991:177-213.
[12] Craig RG. “Restorative dental materials. 9th ed. St Louis: Mosby- Year Book”, Inc, 1993:502-50.
[13] Faber BL. “Lower cast metal base denture”. J Prosthet Dent 1957 ; 1 : 51-4.
[14] Mattoo KA. “The need of additional tissue relief required under a minor connector”. J Clin Res Dent 2019; 2 : 1-2.
[15] Kumar L , Mattoo KA, Yunus N, Singh M, Yadav A. “Comparative evaluation of pressure produced on maxillary denture bearing areas by different impression techniques-an in vivo study”. Int J Oral Health Sci Adv 2015; 3: 38-43
[16] Zachariasen RD. “Oral manifestations of menopause”. Compendium 1993; 14: 1586‑91.