Abstract:

Manystudies have been devoted to the adaptive power-line interference (PLI) canceller design for ECG signal processing. However, almost all existing PLI canceller are developed for applications in which the presence of PLI is assumed a priori. The implementation of adaptable PLI canceller using Least Mean Square (LMS) algorithm to remove the power-line interference (50/60 Hz) from electrocardiogram (ECG) is proposed in this article. The adaptable PLI canceller adjusts its parameters automatically to remove the PLI. Experimental results demonstrate performance of these proposed algorithms.

Keywords:

PLI, LMS algorithm, Electrocardiogram

References:

[1]Rafel Ramos, Antoni Manuel-Lazaro, Del Rio "FPGA-based Implementation of an adaptive canceller for 50/60 Hz interference in Electrocardiography" IEEE Transactions on Instrumentation and Measurement, Vol. 56, No. 6, December 2007.
[2]Maryam Butt, Nauman Razzaq, Ismail Sadiq, "Power Line Interference removal from ECG Signal using SSRLS Algorithm" 9th International Colloquium on Signal Processing and Applications,  2013.
[3]Yue-Der Lin, Yu Hen Hu "Power Line Interference Detection and Suppression in ECG Signal Processing," IEEE Transactions on Biomedical Engineering, Vol.55, No.1 January2008.
[4]H. N. Bharat, K. M. M. Prabhu, "A New LMS based Adaptive Interference Canceller for ECG Power Line Removal," International Conference on Biomedical Engineering February, 2012.
[5]Alireza K. Ziarani, Adalbert Konrad "A Nonlinear Adaptive Method of Elimination of Power Line Interference in ECG Signals,"IEEE Transactions on Biomedical Engineering, Vol.49, No.6 June 2002.
[6]Martens S.M.M., Bergmans J.W.M. and Oei S.G..,(2004) " A Simple adaptive interference cancellation method for power line reduction in electrocardiography”, proceeding of 25th  Symposium on Information Theory in the Benelux, pp. 49-56.
[7]Martens S.M.M., Mischi M.,Oei S.G, and Bergmans J.W.M.  (2006) " An improved  adaptive power line interference canceller for electrocardiography”, IEEE Transactions on Biomedical Engineering, Vol.53, pp. 2220-2231.
[8]B. Widrow et al ‘”Adaptive noise cancelling :    principles and application.” proceeding of the IEEE , Vol.63,no.12.pp.1692- 1716.dec.1975.
[9]Ioan Tudosa , Narcis adochiei , “FPGA Approch of an Adaptive filter for ECG Signal processing” EPE-2012.PP. 25-27
[10]R. Romas , A. Manuel et al “Application by means of FPGA of an adaptive canceller 50 Hz interference in electro-cardiographyIEEE Instrumentation and Measurement Technology.2001
[11]Mohammed Bahoura , Hassan Ezzaidi , “FPGA-Implementation of a sequential Adaptive Noise Canceller using Xilinx SystemGenerator” 2009 International conference on Microelectronics
[12]S. Banerjee and A .Sinha , “Performance analysis of different DSPalgorithms on advanced microcontroller and FPGA”. Proc .OfACTEA, pp.6009-613,15 -17 july 2009
[13]N. Jindapetch et al “FPGA implementation of an ADALINE filter for power –line noise cancellation in surface electromyography signals”2011 ELSEVIER.